1000/300 V, PTFE Wire
MIL-DTL-16878/5 (TYPE EE)
(1000V)
UL AWM 1180 (300V)
NEMA HP3
-60°C to +200°C
Stranded or solid silver-plated
copper conductor
PTFE insulation
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
Part No.
Wire Size Stranding
Insulation
Thickness
Nominal
Diameter
NEMA
HP3
Type
AWG mm
2
AWG mm Inch mm Inch mm
5874 24 0.24 19/36 19 x 0.13 0.015 0.37 0.054 1.37 EEXBEE
5875 22 0.38 19/34 19 x 0.16 0.014 0.36 0.060 1.52 EEXBFE
5876 20 0.62 19/32 19 x 0.20 0.014 0.36 0.068 1.73 EEXBGE
5877 18 0.96 19/30 19 x 0.25 0.015 0.37 0.079 2.01 EEXBHE
5878 16 1.23 19/29 19 x 0.29 0.016 0.41 0.089 2.26 EEXBJE
5879 14 1.94 19/27 19 x 0.36 0.017 0.43 0.106 2.69 EEXBKE
5879/10 10 4.74 37/26 37 x 0.40 0.017 0.43 0.145 3.68 EEXBMG
5879/12 12 3.08 19/25 19 x 0.45 0.017 0.43 0.125 3.18 EEXBLE
5879/8* 8 8.61 133/29 133 x 0.29 0.020 0.51 0.209 5.31 EEXBNL
*Not UL AWM 1180.
Insulation Colors: White • Black • Red • Green • Yellow • Blue • Brown • Orange • Slate • Violet
Parts 5878, 5879, 5879/8, 5879/10, 5879/12: white only.
600 V, ETFE or PTFE Wire
SAE AS22759/11
(MIL-DTL-22759/11)
SAE AS22759/16
(MIL-DTL-22759/16)
-55°C to +200°C (PTFE)
-55°C to +150°C (ETFE)
Stranded silver-plated copper
conductors (SAE AS22759/11)
Stranded tinned copper
conductor (SAE AS22759/16)
ETFE or PTFE insulation
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
PTFE, SAE AS22759/11, -55°C to +200°C, Silver-Plated Copper Conductors
Part No.
Wire Size Stranding
Insulation
Thickness
Nominal
Diameter
AWG mm
2
AWG mm Inch mm Inch mm
AT261938 26 0.15 19/38 19 x 0.10 0.010 0.25 0.038 0.97
AT241936 24 0.24 19/36 19 x 0.13 0.009 0.23 0.043 1.09
AT221934 22 0.38 19/34 19 x 0.16 0.009 0.23 0.049 1.24
AT201932 20 0.62 19/32 19 x 0.20 0.011 0.28 0.058 1.47
AT181930 18 0.96 19/30 19 x 0.25 0.010 0.25 0.068 1.73
AT161929 16 1.23 19/29 19 x 0.29 0.010 0.25 0.075 1.90
AT141927 14 1.94 19/27 19 x 0.36 0.011 0.27 0.090 2.29
AT121925 12 3.08 19/25 19 x 0.45 0.013 0.32 0.111 2.82
ETFE, SAE AS22759/16, -55°C to +150°C, Tinned Copper Conductors
Part No.
Wire Size Stranding
Insulation
Thickness
Nominal
Diameter
AWG mm
2
AWG mm Inch mm Inch mm
AZ241936 24 0.24 19/36 19 x 0.13 0.011 0.27 0.045 1.14
AZ221934 22 0.38 19/34 19 x 0.16 0.011 0.28 0.052 1.32
AZ201932 20 0.62 19/32 19 x 0.20 0.011 0.28 0.060 1.52
AZ181930 18 0.96 19/30 19 x 0.25 0.012 0.29 0.071 1.80
AZ161929 16 1.23 19/29 19 x 0.29 0.013 0.33 0.079 2.01
AZ141927 14 1.94 19/27 19 x 0.36 0.013 0.33 0.093 2.36
AZ123728 12 2.97 37/28 37 x 0.32 0.014 0.34 0.114 2.90
Insulation Colors: White • Black • Red • Green • Yellow • Blue • Brown • Orange • Slate • Violet