Installation User guide

Communicationwiththeheadendmaybeveriedbyclickingonthe“Status”link,whichwilldisplaykey
parameters including upstream and downstream power levels, and the cable modem’s IP address, which
conrmsconnectivity.
4.0 Verifying Installation and Network Connectivity (applies to all power supplies), cont'd.
4.2 Locally via a Web browser
ConguringtheEDH4transponder
Connect a computer’s network port to the transponder’s Ethernet port using a standard network cable.
Launch an Internet browser and enter 192.168.100.1 into the Address. The transponder will return the
Webpageshownbelow.Clickon“Cong”todisplaytheavailablepowersupplytypes,andsingle/Dual
IPcongurations.ClickontheonethatmatchestheconnectedpowersupplyanddesiredIPmode.Click
on“Apply,”andwhenpromptedforaUserNameandPassword,enter“Tollgrade”(withoutthequotes)in
bothplacesandclickon“OK.”
Thetransponderwillreset(theLEDswillgothroughatypicalpowerupsequence)andbegin
communicating with the power supply and the cable network.
745-419-C4-001Rev.A(09/2009)
9
Figure 8, Conguration Screen [selection of power supply shown]
Figure 9, Status Information Screen