Service manual

58 BRAVE Steel User and service manual
5.10 Parameter overview
Parameter
Value
Meaning
Basic
1
tt nn…
number nn under button tt
-
2
tt nn…
number nn under button tt
-
31
r m
relay r works in regime m (1-8)
11 21
31
r* tt
button tt causes switching on of relay r in
regime m=6 (01-99)
01
32
rp hh...
In regime DAY + NIGHT password hh...
for relay r, in order p=1-5, for 1 impulse
and p=* for 2 impulses (00-999999)
-
33
rp hh...
In regime DAY password hh... for relay r,
in order p=1-5, for 1 impulse and p=* for 2
impulses (00-999999)
-
34
rp hh...
In regime NIGHT password hh... for relay
r, in order p=1-5, for 1 impulse and p=* for
2 impulses (00-999999)
-
35
r aa
command aa from the phone for switching
on relay r 1 impulse (00-99,*0-*9)
155 266
36
r cc
command aa from the phone for switching
on relay r 2 impulses (00-99,*0-*9)
150 260
37
r ss
time ss [sec] of relay r switch on for time
t1/t4 (01-99)
105 205
38
r p
Control of relay r during incoming call
(0/1)
11 21
39
xx
period xx [sec] between switching on of
relays 1 and 2 in regime m=5 time length
t3 (01-99)
10
30
r zz
period zz [sec] between impulses for
switching on 2 impulses of relay r time
length t2/t5 (01-99)
105 205
3*
r e
Exit button for relay r (0/1/2)
10 20
3#0
p
p = 1 enabled / disabled p = 0 connection
code relay COSW (0/1)
0
3#1
abcd
activation code 1 pulse from buttons
(0000-1111)
0000
3#1
abcd
activation code 1 pulse from phone
(0000-1111)
0000
3#1
abcd
activation code 2 pulses from buttons
(0000-1111)
0000
3#1
abcd
activation code 2 pulses from phone
(0000-1111)
0000
3#5
abcd
activation code from other modes of switch
(0000-1111)
0000
41
v
Type of choice v ton/impulse (0/1)
0