Service manual
BRAVE Steel – User and service manual 45
5.4 Time parameters
Parameter
Value
Meaning
Basic
51
q
Number of rings before the Brave picks up
(1-9)
2
q – The number of rings before an incoming call is picked up. The Brave
picks up between rings 2 secs. after detecting the q-th ring. It is possible
to set the number of rings between 1 and 9.
Parameter
Value
Meaning
Basic
52
d
Maximum length of a call (0-9,*,#)
2
d – The maximum length of time for which the Brave is
busy. It is possible to prolong this time during the
call by choosing a key (* or #) from the phone
(parameter 42). The setting of this time is in
accordance with the adjacent table.
Parameter
Value
Meaning
Basic
53
w
Time between button presses (1-
9)
2
w – maximum time [in seconds] between button presses [range 1 - 9]
Normal buttons
- Relay switch on – if the time between presses is longer than time w,
then the code will not work correctly.
- Choice of number – if the pressed button is the first number of a
password to switch on a relay then the choice is delayed by time w.
Keyboard
- Switch on Relay – if the time between presses is longer than the time
w then the code will not work correctly.
- Choosing of number
- Choose from the phone, if the time after the last pressed button
is longer than time w, then the choice commences, if the number
is incomplete, it is necessary to disconnect (press the X key )
and repeat the choice;
- Choose from the memory, if the time after the last pressed button
is longer than the time w, then the choice needs to be repeated.
Time
[min]
Option
0,5
0
1 - 9
1 - 9
15
*
30
#