Service manual

BRAVE Steel User and service manual 39
Example:
Command for switching on 2 relays 1 impulse is for example *8, the command for
disconnection is *8 and the command for switching on 2 relays 2 impulses is *9.
Programming: 352*8 ♫ , 432*8 ♫ , 362*9 ♫.
If you are in conversation with the Brave, the command to open a gate would be button
9, the first impulse starts and the gate opens, the second impulse stops it, the time the
gate is opened "opened space" is set by time between the impulses (parameter 30)
after people enter press 8, then Brave makes 1 impulse and disconnects, gate closes.
Parameter
Value
Meaning
Basic
37
r ss
time ss [sec] of relay r on for time t1/t4
(01-99)
105 205
r relay number [1-2]
ss time t1 / t4 for which relay 1 / 2 is switched on [2 spaces 00-99], where
time 00 means 0,5sec
Parameter
Value
Meaning
Basic
38
r p
relay r control during incoming call
(0/1)
11 21
r relay number [1-2]
p parameter whether it is allowed p=1 or disallowed p=0 to control relay
during incoming call.
To prohibit „control‟ during an incoming call, for use with relay 2 in mode 1 for
controlling a garage door, so the electronics open the garage door and the car
passing through the door, closes the door. Then control from the phone could
result in a permanently opened door (i.e. the door doesn‟t close because car
didn‟t enter).
Parameter
Value
Meaning
Basic
39
xx
time xx [sec] between switching on relays
1 and 2 in regime m=5 - time t3 (01-99)
10
xx time t3 between switching on relays 1 and 2 when regime m=5 is set
(gradual opening) [2 spaces 00-99] ], where time 00 means 0,5sec
Parameter
Value
Meaning
Basic
30
r zz
time zz [sec] between impulses for
switching on relay r 2 impulses- time t2/t5
(01-99)
105 205
r relay number [1-2]
zz time t2 / t5 between first and second impulse for switching on relay 1 / 2
[2 spaces 00-99], where time 00 means 0,5sec