Service manual

36 BRAVE Steel User and service manual
2. second button is supposed to dial 123#1*2Flash3 during day and night, then the
programming is 102123#1 ** 2 *# 3 and wait for ♫, then 202123#1 ** 2 *# 3 and wait
for ♫
Note. If you are not using regime Day/night or regime 2 groups of numbers, then it is
recommended to set regime Day/Night (parameter 47) and then set the same code
for switching over Day/Night (parameters 45 and 46). His way it is guaranteed that
Brave will always be in Day regime and you can only programme telephone numbers
for the day regime (parameter 1).
5.2 Relays
Parameter
Value
Meaning
Basic
31
r m
relay r operates in regime m (1-8)
11 21
r relay number [1-2]
m relay regime [1-8 for r=1 is not regime m=5]
regimes m=1, 4, 5, 6 are explained in detail in Relay Regimes Tab. 1 on page
30
m=1 mode relay switched on with command (internal code) or with a
password (external) 1 impulse for length of time t1/t4 (use for electric
locks) or 2 impulses when it switches on for time t1/t4, off for t2/t5 and
again switches on for t1/t4 (opening of sliding gates).
m=2 is switched on for time when the line is picked up (camera) switches on
when system picks up and off when it disconnects.
m=3 is switched on for time when the line is picked up and extra time t1/t4
after disconnection (lights) - switches on for time when the line is picked
up and extra time t1/t4 after disconnection (for this time the line is busy,
with version (C) is after switching DIP 3, 4 and setting of parameter 64
line after t1/t4 disconnected)
m=4 regime button switched on when any button is pressed and off after
t1/t4 (use is for example connection of external bell or siren)
m=5 regime gradual opening into this regime it is possible to set only relay
2, because relay 1 will then automatically be set to m=1. With command
(internal code) or password (external code) relay 1 is activated for length
of time1, then time t3 is running before relay 2 is switched, then relay 2 is
activated for time t4 and after the system disconnects. If given command
or password answers to 2 impulses then in the sequence there will be
always 2 impulses separated by time t2/t5. Explanation is in Tab.1.
Note. Command or password for relay 1 starts the whole sequence, if you use
command or password for relay 2 then only relay 2 is controlled in the same way
as in regime m=1.
m=6 switches on depending on pressed button (it is set in parameter 31r*). In
this way it is possible to choose only one button for each relay, which
when pressed switches on relay for time t1/t4. This regime is used
instead of connecting separate doorbell to the system.