Service manual

30 BRAVE Steel User and service manual
Regime m = 4
Action
Note
Relay
Press buttons
Any number other than
in 311* or 312*
Button set in 311* or
312*
Regime m = 6
Action
Note
Relay
Press of the button
Any number other than
in 311* or 312*
-
-
Button set in 311* or
312*
Note t1 time of connection of relay 1 (parameter 371)
t2 time between impulses of relay 1 (parameter 301)
t3 time between connections of relay 1 and 2 (parameter 39)
t4 - time of connection of relay 2 (parameter 372)
t5 - time between impulses of relay 2 (parameter 302)
Tab. 1 Table of relay controls
3.3 Person in the building
The person in the building means the person who is in telephone contact
with the Brave entry system (i.e. Mr Smith).
3.3.1 Outbound call
An outbound call is a call from the Brave system (i.e. started by a visitor).
Once the system has been dialled, a phone inside of the building rings and on
pick up it is possible to talk to the visitor at the door. By choosing a code it is
possible to switch on a relay (parameter 35) if it is set in mode m=1 or m=5,
switch over the Day/Night regime (parameter 45, 46) and disconnect the
connection (parameter 43). 10sec before the end of the call (parameter 52) the
system sends a notice about the end of the call but choosing a code
(parameter 42) it is possible to pro-long the call. By replacing the handset the
call is terminated (the switchboard phone will send a system busy tone and the
system will disconnect). There is one more option, disconnection of line after
repeat pressing of the same button (parameter 4*).