User guide
BRAVE – user guide 
33 
Parametr 
Value 
Description 
Default 
3#0 
p 
 p = 1 enabled / disabled p = 0 connection 
code relay COSW (0/1) 
0 
p   – turns on transmission serial code to activate the first switch. 
CAUTION - at activation this function never connect to the circuit electric lock 
without  board  COSW  -  code  relay  -  threatens  to  destroy the  relay  in  Brave 
communicator! 
The following codes may be the same or different for the resolution switching on 
multiple parallel connected relay code. 
Parametr 
Value 
Description 
Default 
3#1 
abcd 
activation code 1 pulse from buttons 
   (0000-1111) 
0000 
abcd –  Brave  sends  a  serial  code  for  the  code  relay  (COSW)  after 
evaluation code from keys (keyboard) namely for 1 pulse 
Parametr 
Value 
Description 
Default 
3#2 
abcd 
activation code 1 pulse from phone 
   (0000-1111) 
0000 
abcd –  Brave  sends  a  serial  code  for  the  code  relay  (COSW)  after 
evaluation code from telephone (DTMF) namely for 1 pulse 
Parametr 
Value 
Description 
Default 
3#3 
abcd 
activation code 2 pulses from buttons 
   (0000-1111) 
0000 
abcd –  Brave  sends  a  serial  code  for  the  code  relay  (COSW)  after 
evaluation code from keys (keyboard) namely for 2 pulses 
Parametr 
Value 
Description 
Default 
3#4 
abcd 
activation code 2 pulses from phone 
   (0000-1111) 
0000 
abcd –  Brave  sends  a  serial  code  for  the  code  relay  (COSW)  after 
evaluation code from telephone (DTMF) namely for 2 pulses 
Parametr 
Value 
Description 
Default 
3#5 
abcd 
activation code from other modes of switch 
   (0000-1111) 
0000 
abcd –  Brave  sends  a  serial  code  for  the  code  relay  (COSW)  after 
evaluation code from other modes m switch 1 