10.1 Denitions and Settings
The following tables display commonly-congured Alpha MIB parameters and provide specic information
with regard to functionality, options, OIDs, types and variables.
Parameter OID Description Access Type Value
atiMgntSnmp 1.3.6.1.4.1.926.1.3.1 Object
Identier
SNMP TRAP ADDRESSES
atiMgmtSnmpTrapTable 1.3.6.1.4.1.926.1.3.1.1 Object
Identiers
atiMgmtSnmpTrapAddress.1 1.3.6.1.4.1.926.1.3.1.1.1.2.1 SNMP Trap Address (1) Read/Write IP Address 0.0.0.0 (default)
atiMgmtSnmpTrapAddress.2 1.3.6.1.4.1.926.1.3.1.1.1.2.2 SNMP Trap Address (2) Read/Write IP Address 0.0.0.0
atiMgmtSnmpTrapAddress.3 1.3.6.1.4.1.926.1.3.1.1.1.2.3 SNMP Trap Address (3) Read/Write IP Address 0.0.0.0
atiMgmtSnmpTrapAddress.4 1.3.6.1.4.1.926.1.3.1.1.1.2.4 SNMP Trap Address (4) Read/Write IP Address 0.0.0.0
SECURE SNMP ACCESS ADDRESS
atiMgmtSnmpAccessTable 1.3.6.1.4.1.926.1.3.1.2 Object
Identiers
atiMgmtSnmpAccessAddress.1 1.3.6.1.4.1.926.1.3.1.2.1.2.1 Secure IP Address (1) Read/Write IP Address 0.0.0.0 (default)
atiMgmtSnmpAccessAddress.2 1.3.6.1.4.1.926.1.3.1.2.1.2.2 Secure IP Address (2) Read/Write IP Address 0.0.0.0
atiMgmtSnmpAccessAddress.3 1.3.6.1.4.1.926.1.3.1.2.1.2.3 Secure IP Address (3) Read/Write IP Address 0.0.0.0
atiMgmtSnmpAccessAddress.4 1.3.6.1.4.1.926.1.3.1.2.1.2.4 Secure IP Address (4) Read/Write IP Address 0.0.0.0
SNMP ACCESS ENABLE
atiMgntSnmpAccess 1.3.6.1.4.1.926.1.3.1.3.0 Object
Identiers
atiMgmtSnmpSnmpv1Access 1.3.6.1.4.1.926.1.3.1.3.1.0 SNMPv1 Access to Power
Supply Data
Read/Write Integer 1 = Disable
2 = Enable (Default)
atiMgmtSnmpSnmpv2Access 1.3.6.1.4.1.926.1.3.1.3.2.0 SNMPv2c Access to Power
Supply Data
Read/Write Integer 1 = Disable
2 = Enable (Default)
CPE & SECURITY KEY (Dual IP)
atiMgmtSnmpAlphaSetAccess 1.3.6.1.4.1.926.1.3.1.3.3.0 "Set to Data Access Key
CIBSET (default)"
Read/Write Octet String Set to match the value
of the Data Access Key
atiMgmtSnmpAlphaSetKey)
atiMgmtSnmpAlphaSetKey 1.3.6.1.4.1.926.1.3.1.3.4.0 Data Access Key (Dual IP) Read/Write Octet String CIBSET (default)
atiMgmtSnmpCPESetEnabled 1.3.6.1.4.1.926.1.3.1.3.5.0 Corresponds to whether
or not the action taken on
atiMgmtSnmpAlphaSetKey
was successful. Once
enabled, writing 1(false)
to this variable will disable
CPE sets.
Read/Write Integer 1=Disabled (False)
2=Enabled (True)
atiMgmtSnmpSnmpCPEAccess 1.3.6.1.4.1.926.1.3.1.3.6.0 Enables the CPE interface -
Dual IP mode
Read/Write Integer 1=Disabled (Single IP)
2=Enabled (Dual IP)
CPE SETTINGS (Dual IP)
atiMgmtSysMonitoringCpeStaticMode 1.3.6.1.4.1.926.1.3.2.2.5.2.1.0 Method by which the CPE
acquires its IP address
Read/Write Integer 1=DHCP
2=Static
atiMgmtSysMonitoringCpeStaticAddress 1.3.6.1.4.1.926.1.3.2.2.5.2.2.0 When the address source is
static, this is the IP address the
CPE will be assigned.
Read/Write IP Address 0.0.0.0 (default)
atiMgmtSysMonitoringCpeStaticMask 1.3.6.1.4.1.926.1.3.2.2.5.2.3.0 When the address source is
static, this is the mask the
device will use to determine if
other devices are on the local
area network (LAN).
Read/Write IP Address 0.0.0.0 (default)
atiMgmtSysMonitoringCpeStaticGateway 1.3.6.1.4.1.926.1.3.2.2.5.2.4.0 When the address source is
static, this is the IP address of
the gateway the device will use
for accessing devices not on the
local area network (LAN).
Read/Write IP Address 0.0.0.0 (default)
10.0 Alpha MIB Parameters
The Alpha MIB Denitions and Settings are subject to change without notice and should only be used
for advanced diagnostics. The SCTE-HMS MIBs listed in Section 6.0 Data Management should be
implemented for status monitoring & control.