4.0 Using the Local Port
The local port allows a technician to monitor and set XP-DSM parameter values directly using a
personal computer and a Local Port Adapter Cable (Alpha Alpha P/N 745-826-21). Terminal emulation
software is necessary (HyperTerminal is recommended).
NOTE:
Entries in the TEXT Table are transponder parameters
and do not have subsystems.
Example: To Update Read/Write Community String to
“ReadString”
Enter Command: >tex 45 ReadString
Procedure:
1. Launch the terminal emulation software.
2. Hit ENTER to display the menu of CIB tables.
3. Enter >[rst three letters of table] and ENTER
to display the contents of a table.
Subsystem Denitions
BSS Battery System
XM2 Power Supply System
SYS Transponder System
ECM Generator System
SYS-1 06 SNMPv1 1 ENABLED YES
Subsystem
Parameter Index
Parameter
Value
Enumerated Value
Modiable?
Power Supply
Entry Explanation
SELECT FROM : ANALOGS CONFIG COUNTERS DISCRETES
TEXT
>dis
DISCRETES
DEV-A IX NAME VALUE ENM/UNIT SET
----------------------------------------------
BSS-1 00 GENERAL STATUS 0 OK NO
----------------------------------------------
XM2-1 00 GENERAL STATUS 0 OK NO
XM2-1 01 SELF TEST FAIL 0 OK NO
XM2-1 02 LOW BATT VOLTS 0 OK NO
XM2-1 03 HIGH BATT VOLTS 0 OK NO
XM2-1 04 NO BATTERIES 0 OK NO
XM2-1 05 BATT TEMP PROBE 0 OK NO
XM2-1 06 LINE ISOLATION 0 OK NO
XM2-1 07 OUTPUT FAILURE 0 OK NO
XM2-1 08 OUTPUT OVERLOAD 0 OK NO
XM2-1 09 OUTPUT 1 TRIPPED 0 OK NO
XM2-1 10 OUTPUT 2 TRIPPED 0 OK NO
XM2-1 11 CHARGER FAILURE 0 OK NO
XM2-1 12 INPUT FAILURE 0 OK NO
XM2-1 13 INV DISCONNECTED 0 OK NO
XM2-1 14 INVERTER TEMP 0 OK NO
XM2-1 15 TAP SWITCH 0 NO NO
XM2-1 16 PIM OPTION 0 NO NO
XM2-1 17 N+1 VALID 0 NO NO
XM2-1 18 SELF TEST 0 OFF YES
XM2-1 19 TEST INHIBIT 0 YES
XM2-1 20 ACCEPT/FLOAT 0 FLOAT YES
XM2-1 21 INVERTER ENABLE 1 ON NO
XM2-1 22 CHARGER ENABLE 1 ON NO
XM2-1 23 RESET OUT 1 1 YES
XM2-1 24 RESET OUT 2 0 NO YES
XM2-1 25 N+1 IN USE 0 NO NO
XM2-1 26 SET DEFAULTS 0 NO YES
XM2-1 27 FACTORY TEST 0 OFF NO
XM2-1 28 TAP FUSE FAIL 0 OK NO
XM2-1 29 CONFIG ERROR 0 OK NO
XM2-1 30 N+1 FAULT 0 OK NO
XM2-1 31 BB-CMM/CMT OPT 0 NO YES
----------------------------------------------
SYS-1 00 AUTO CONFIG 0 ENABLED YES
SYS-1 01 TAMPER ALARM 0 OK NO
SYS-1 02 TAMPER ALM WHEN 0 CLOSED YES
SYS-1 03 MGMT MSG TARGET 0 CPE NO
SYS-1 04 BLOCK CM 0 NO YES
SYS-1 05 BLOCK CPE 0 NO YES
SYS-1 06 SNMPv1 1 ENABLED YES
SYS-1 07 SNMPv2 1 ENABLED YES
SYS-1 08 ALPHA SNMP SETS 1 ENABLED YES
SYS-1 09 TRAP ON NORMAL 0 DISABLED YES
SYS-1 10 HTTP SERVER 1 ENABLED YES
SYS-1 11 HTTP TEXT 0 DISABLED YES
SYS-1 12 PING REQUEST 0 YES
SYS-1 13 GET NEW IMAGE 0 YES
SYS-1 14 COM BUS DAT SIZE 0 9 BIT YES
SYS-1 15 DEVICE RESET 0 RUNNING YES
SYS-1 16 DEBUG MESSAGES 0 ENABLED YES
SYS-1 17 PI CURRENT MODE 0 ENABLED YES
----------------------------------------------
Discrete Table
Baud 19200
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
Serial Communication Settings
OUTPUT2
OUTPUT1ALRI
Battery
Input
Temp
Probe
Battery
Breaker
OUTPUT1B
N+1
N+1
ALM
RDY
COM
LNK
RF
REG
DS
TMPR
CTRL
C
O
M
E
T
H
C
D
A
B
L
O
C
A
L
Power Supply
Result:
SYS-1 06 SNMPv1 0 DISABLED YES
Hit ENTER
>dis sys 1 6 0
Subsystem
Parameter Index
Value
Table
Example Command
To disable SNMPv1, enter the command:
4. To set a parameter value, enter: >[table]
[subsystem] [power supply] [Index] [Value]
ENTER.