1 +12V Ignition Battery Ignition battery Fused 12V from APU.
2 Neg Ignition Battery Ignition Battery Negative from APU.
3 Low Oil Pressure Active LOW signal denotes Low Oil Pressure.
4 Over-Temp Active LOW signal indicates Over Temp.
5 Start Command Active LOW from ECM activates the APU START
relay.
6 Common (Start /Stop) Common return between Start and Stop relays.
7 Stop Command Active LOW from ECM activates the APU STOP relay.
8 Over-Speed Active LOW signal denotes engine RPM was exceeded.
9 Over-Crank Active LOW signal denotes Over Crank Limit is
reached.
10 Engine Run Active LOW signal denotes the Engine is Running.
11 Not Used