Manual
3. Maintenance
45
031-132-B0-001 Rev. A
TM
©2000
Disconnect the sensor from the wire
harness and replace with the new
sensor. Add the opposite piece of the
hook and loop fastener, and reinstall
the sensor.
End of Procedure
3.6 Replacing GAS HAZARD Sensor, continued
Removal and replacement procedure, continued:
NOTE:
Verify the replacement gas sensor is calibrated to detect
the appropriate gas (i.e., Propane or Natural Gas).