User Manual

19
745-680-B2-002, Rev. B
SMU-HR 12-9
End voltage 5Min 10Min 15Min 30Min 1h 3h 5h 10h 20h
1.60V 72.6 46.5 35.4 21.3 10.3 4.43 2.58 1.71 0.95
1.67V 70.0 45.3 35.0 20.9 10.2 4.29 2.57 1.70 0.92
1.70V 66.4 44.9 34.7 19.6 10.0 4.10 2.53 1.69 0.91
1.75V 65.9 44.7 34.4 19.0 9.83 4.00 2.51 1.65 0.88
1.80V 60.7 44.0 31.9 18.1 9.27 3.88 2.43 1.60 0.86
1.85V 55.1 41.8 28.9 16.9 8.71 3.77 2.36 1.56 0.83
SMU-HR 12-18
End voltage 5Min 10Min 15Min 30Min 1h 3h 5h 10h 20h
1.60V 156 99.6 75.9 45.7 25.7 11.1 6.44 4.27 2.24
1.67V 150 97.1 75.0 44.7 25.5 10.7 6.42 4.24 2.16
1.70V 142 96.1 74.4 41.9 25.0 10.2 6.33 4.21 2.13
1.75V 141 95.8 73.7 40.7 24.6 10.0 6.28 4.16 2.08
1.80V 130 94.4 68.4 38.8 23.2 9.71 6.08 4.11 2.06
1.85V 118 89.5 62.0 36.3 21.8 9.41 5.89 4.05 2.03
5.2 Discharge Data with Constant Power
Wattage values for each battery model as a function of time and voltage with constant Watts
per cell @ 77°F/25°C.
SMU-HR 12-35
End voltage 5Min 10Min 15Min 30Min 1h 3h 5h 10h 20h
1.60V 290 186 142 85.3 42.3 18.3 10.6 7.04 3.70
1.67V 280 181 140 83.5 42.1 17.7 10.6 7.00 3.56
1.70V 265 179 139 78.2 41.3 16.9 10.5 6.95 3.52
1.75V 264 179 138 75.9 40.6 16.5 10.4 6.86 3.43
1.80V 243 176 128 72.4 38.2 16.0 10.0 6.70 3.36
1.85V 220 167 116 67.8 35.9 15.5 9.72 6.56 3.30
SMU-HR 12-55
End voltage 5Min 10Min 15Min 30Min 1h 3h 5h 10h 20h
1.60V 385 257 203 125 74.1 31.4 20.3 11.2 5.87
1.67V 373 253 198 124 73.7 31.3 20.2 11.1 5.82
1.70V 360 252 197 124 73.6 31.2 20.1 11.0 5.77
1.75V 353 245 194 123 73.3 31.1 19.8 10.9 5.71
1.80V 345 239 191 122 72.6 30.9 19.5 10.8 5.66
1.85V 327 224 152 114 68.2 28.5 17.7 10.4 5.45