User's Manual

2.5 Requirements of Reliability,
Maintainability and Quality
# Feature Detailed Description
2.5.1 MTBF
Ÿ
Mean Time Between Failure > 30,000 hours
2.5.2
Maintainability
Ÿ
There is no scheduled preventive maintenance required
2.5.3
Quality
Ÿ
The product quality is followed-up by Alpha Networks
factory quality control system
2.6 Environmental Requirements
# Feature Detailed Description
2.6.1 Operating
Temperature
Conditions
Ÿ The product is capable of continuous reliable operation
when operating in ambient temperature of 0 to +40.
2.6.2
Non-Operating
Temperature
Conditions
Ÿ
Neither subassemblies is damaged nor the operational
performance is degraded when restored to the operating
temperature after exposing to storage temperature in the
range of 20
to +75
.
2.6.3 Operating
Humidity
conditions
Ÿ The product is capable of continuous reliable operation when subjected
to relative humidity in the range of 10% and 90% non-condensing.
2.6.4
Non-Operating
Humidity
Conditions
Ÿ
The product is not damaged nor the performance is
degraded after exposure to relative humidity ranging from
5% to 95% non-condensing
Company Confidential