Instruction manual
Eagle 450 Installation and Technical Manual, Rev. 00
Chapter 2 -
Specifications
GENERAL SPECIFICATIONS
Temperature/Humidity Temperature: 60
°
to 90
°
F (15.6
°
to 32.2
°
C); 10
°
C per hour
maximum fluctuation;
Humidity: 20% to 80%, non-condensing
Power Requirements USA and Canada: 115 VAC (90 to 132 VAC), 47 to 63Hz
International: 230 VAC (180 to 264 VAC), 47 to 63Hz
Maximum AC Power Consumption AM-138 board: 5 amps at 115 volts or 2.5 amps at 230 volts
Note: due to varying peripherals, it is impossible to determine
total power requirements for complete system.
Maximum DC Power Requirements +5 volts: 4.3A with 256MB DRAM; 3.9A with 8MB DRAM
+12 volts: less than 100mA
Figures for AM-138 board only
Electromagnetic Interference Complies with US FCC rules and regulations, Class A
System Dimensions Height: 17.75” (44.5 cm)
Width: 9” (22.9 cm)
Depth: 17” (43.1 cm)
Weight: Up to 26 lb. (12 kg)
Enclosure Composition Sheet metal and plastic
Additional Features Clock/calendar with battery backup
Front panel with status and diagnostic display
32-bit, bus-master RISC SCSI controller
Programmable interval timer
AC power failure detect
Remote reset option
Security lock
CMOS setup feature
Dedicated UPS monitoring port
Optional AM-338 RJE interface