Instruction manual

Troubleshooting Page 5-5
Eagle 450 Installation and Technical Manual, Rev. 00
Front Panel
Status Code
Description
46 UPS inverter is running and a low battery condition exists. Only
2 minutes
of power remaining!
System shutdown is imminent.
47 Not valid, system dead.
48 An internal fault has been detected in the UPS.
49 An internal fault has occurred in the UPS and it is in bypass.
4A - 4E Not valid.
4F UPS cable has been unplugged from UPS port.
88 Trying to execute an unimplemented SVCA (Monitor) call.
95 Logger CREATE error.
96 Logger CLOSE error.
97 Logger FILOTX error.
98 Logger OPENA error.
99 Logger semaphore not available.
B0 CMOS batteries need to be replaced. Data that was stored in CMOS RAM is
not guaranteed.
B1 The battery voltage dropped temporarily (i.e., after replacing the batteries).
The initial CMOS parameters are not guaranteed. Access the CMOS setup
routine by pressing Reset, then pressing the
ESC
key when the code "C5"
appears on the front panel. Re-enter CMOS settings.
C5 Do you want to enter CMOS setup? You have three seconds to press the
ESC
key on the boot terminal.
CC The computer is testing the CMOS RAM for proper operation after
detecting a CMOS checksum error.
CE CMOS parameter checksum error. This code will flash on the front panel for
several seconds.
CF CMOS RAM failure. The system will try to boot using the default CMOS
settings shown on page 4-4. Contact the Alpha Micro Technical Assistance
Center.
D0 Tried deleting all three valid timer chips and all failed.
EF System has detected an attempt to write outside of the supervisor stack area.
F On boot-up, memory is being cleared and sized.
F0 Bus error was encountered.
F1 Address error was encountered.