Instruction manual
Page 5-4 Chapter Five
Eagle 450 Installation and Technical Manual, Rev. 00
Front Panel
Status Code
Description
2F Bootup from the alternate boot device failed because of an invalid boot
device selection. Access the CMOS setup routine by pressing Reset, then
pressing the
ESC
key when the code "C5" appears on the front panel. Verify
the device and unit number settings on the CMOS menu.
33 Initializing the primary boot device. If the boot stops at this point, it may
indicate a hardware problem with the primary boot device. When booting
from a disk, this code may remain on the display for a short time after
you've turned the power on, while the disk drive spins up to operating speed.
34
While booting:
reading the Master File Directory (MFD) from the primary
boot device. An error at this point indicates disk problems.
During normal operation:
unimplemented integer instruction encountered.
35 Searching for the User File Directory (UFD) for account [1,2] on first
logical of the primary boot device.
38 Searching for account [1,4] on the first logical of the primary boot device.
An error at this point may indicate disk problems. Reload the latest version
of the system software.
39 The computer is looking for the system monitor file in [1,4] of the primary
boot device. If this file is missing, reload the latest version of the system
software.
3A Loading the AMOS monitor from the primary boot device. If an error
occurs at this point, reload the latest version of the system software.
3b Beginning to execute the AMOS monitor from the primary boot device. If
an error occurs at this point, reload the latest version of the system software.
3F Bootup failed because of an invalid primary boot device selection. Access
the CMOS setup routine by pressing Reset , then pressing the
ESC
key when
the code "C5" appears on the front panel. Verify the device and unit number
settings on the CMOS menu.
40 UPS inverter on. Normal operation recovering from an AC power failure.
Only displays if the UPS status cable is installed on the UPS port.
41 UPS is bypassed. System running without UPS battery protection. Please
turn on UPS run switch.
42 UPS inverter on, AC power failure detected, and the system is running off
batteries. This status is updated every second that the AC power is off.
43 Not valid, system inoperative.
44 UPS is on, and batteries are low. Batteries are recharging, please check.
45 UPS is bypassed and batteries are low.