Instruction manual
Installation Page 4-7
Eagle 450 Installation and Technical Manual, Rev. 00
3.
Make all the necessary changes to TEST.INI. Save the file when exiting AlphaVUE by pressing
the
ESC
key and typing
F
. Some of the common changes you’ll make are discussed below.
4.
Make sure no one else is using the computer and use MONTST to insure TEST.INI works as
expected:
LOG OPR:
ENTER
MONTST TEST.INI
ENTER
5.
After you have successfully tested TEST.INI and you are satisfied with the results, copy it back
to AMOS32.INI.
Be careful not to rename the TEST.INI file too soon. You might want to let the computer
run awhile to test out the new configuration before you rename it. If you decide you don't
want to keep the new configuration, you can always press the Reset button to reboot with
your former system initialization file.
Follow this procedure any time you modify the system initialization file.
Do not change any lines in the system initialization file unless you're familiar with them and
understand their ramifications. For more information on the initialization file, refer to the
System
Operator's Guide to the System Initialization Command File, DSO-00002-00
.