Instruction manual

Configuration Page 3-13
Eagle 450 Installation and Technical Manual, Rev. 00
WHT/BLU
BLU/WHT
WHT/ORG
ORG/WHT
WHT/GRN
GRN/WHT
WHT/BRN
BRN/WHT
P1+
P1-
P2+
P2-
P3+
P3-
P4+
P4-
5
4
3
6
2
7
8
1
RXD
RTS
TXD
DTR
CTS
GND
DCD
SHLD
5
4
3
6
2
7
8
1
3
4
2
20
5
7
8
1
TXD
CTS
RXD
DTR
RTS
GND
DCD
SHLD
SIGNAL PAIR # RJ-45
AM-90 BOARD
GRN
RED
BLK
YEL
ORG
BRN
SLT/WHT
BLU
RJ-45 SIGNAL
DB25
PINOUTS
PARALLEL PATCH CORD
MALE DB25
ADAPTER = MODEM
PDB-00359-53
Use this kit to connect a modem to the Eagle 450 with full handshaking support.
Figure 3-5: PDB-00359-53 External Cabling Kit
WHT/BLU
BLU/WHT
WHT/ORG
ORG/WHT
WHT/GRN
GRN/WHT
WHT/BRN
BRN/WHT
P1+
P1-
P2+
P2-
P3+
P3-
P4+
P4-
5
4
3
6
2
7
8
1
RXD
RTS
TXD
DTR
CTS
GND
DCD
SHLD
5
4
3
6
2
7
8
1
2
5
3
8
20
7
4
1
TXD
CTS
RXD
DCD
DTR
GND
RTS
SHLD
SIGNAL PAIR # RJ-45
AM-90 BOARD
GRN
RED
BLK
YEL
ORG
BRN
SLT/WHT
BLU
RJ-45 SIGNAL
DB25
PINOUTS
PARALLEL PATCH CORD
MALE DB25
ADAPTER = CRTs/PRINTERS
PDB-00359-54
Use this kit to connect all terminals and printers to the Eagle 450 AM-90 ports.
CRT or printer busy
*
*
Figure 3-6: PDB-00359-54 External Cabling Kit
Both of the above cable kits require a shielded parallel patch cord with RJ-45 connectors at each
end, like the 10 foot PRA-00189-10 cables supplied in the PDB-00359-56 cabling kit.