Instruction manual
Installation Instructions: Roadrunner 030/040 Eagle Upgrade Page 3
PDI-03500-00, Rev. B01
To perform the SSD encodement, enter the following command:
SCZPIC
RETURN
You will be prompted for a Product Installation Code (PIC).
Enter the same PIC used when you originally installed your Roadrunner board. Enter the PIC
carefully and press
RETURN
.
After a brief pause, you will be returned to AMOS command level and you can proceed with the
remainder of the installation. If you see the error message
?Improper SSD
after you have
rebooted the computer, it probably means you have entered the PIC incorrectly.
As mentioned above, you cannot PIC-encode the same overlay twice! To re-encode the
dispatcher software, type this command first:
COPY SCZDSP.OVR=SCZDSP.SAV
RETURN
You will now be able to re-encode the dispatcher. If you receive the same error, after rebooting
the computer , check with your dealer to make sure you have the correct PIC for your computer.
2. Next, embed the Roadrunner SCSI driver into your AMOS monitor:
LOG SYS:
RETURN
MONGEN
RETURN
Input monitor name: AMOS.MON
RETURN
New disk driver: SCZRR.DVR
RETURN
New language definition table name:
RETURN
New monitor name: TEST.MON
RETURN
SAVE TEST.MON
RETURN
Testing the New Software
Now that you have entered the PIC for the SCSI dispatcher and created a monitor called TEST.MON,
you need to verify the software boots in your old configuration. Type:
LOG OPR:
RETURN
MONTST TEST,AMOS32.INI
RETURN
(or AMOSL.INI, depending on the configuration)
Watch your display screen as the system boots and make sure no errors are displayed as the initialization
file is processed. If the system boots without error, type:
COPY AMOS32.MON=TEST.MON
RETURN
or, if your computer uses a monitor called AMOSL.MON, type:
COPY AMOSL.MON=TEST.MON
RETURN
Reboot the computer by pressing the reset button and do a complete check of all the hardware on your
computer—printers, magnetic tape drives, etc.