Instruction manual

Configuring the AM-138-10 Page 11
Eagle 250 Upgrade Instructions, Rev. A00
AM-138-10 Jumpers
Jumper
Number Jumper Name
Default
Setting Notes
JP1 RR-EN out When IN, enables remote reset through serial
port 0 (this is not supported through AM-90
card); when out, allows remote reset cable
attachment at P8. See page 13.
JP2 Level7 Select UPS 3-pin jumper; set to two pins at UPS side. When
set to FP, front panel Turbo switch enables
Level7 diagnostic. Not user configurable.
JP3 20
16
IN
out
Ethernet bus clock select. Not user configurable.
JP5 TERMPWR EN SCSI bus termination voltage,
EN = Enabled, DS = Disabled. User may change.
JP6 DISC IN Not user configurable
JP7 Memory Size
Select
See Table 3-2 Memory size configuration. Installer must
configure.
JP8 32
16
25
20
33
out
out
out
out
IN
Not user configurable.
JP9 33
50
66
SP
out
out
IN
out
Not user configurable.
Table 4-1: AM-138-10 Board Jumper Configuration