Specifications
AM-6060 Network Server AMB98-07 Page
________________________________________________________________________________
13
Table 3. External SCSI Cables
Use This Cable to Connect Chassis to Device
External SCSI
Connector on
AM-6060 Chassis
Connector on
External
SCSI Device
Cable
Part Number
Description
68-pin 50-pin PDB-00440-80 Cable, 50-pin Centronics to 68-pin
External SCSI, 3 ft.
68-pin 50-pin PDB-00440-81 Cable, 50-pin Centronics to 68-pin
External SCSI, 6 ft.*
68-pin 68-pin PDB-00440-82 Cable, Wide SCSI, 68-pin/Male, 68-pin
Male
* To use a 6 ft. cable and keep within Wide SCSI cable guidelines, an AM-6060 must be equipped
with an AM-441-00 Wide SCSI Bus Repeater.
________________________________________________________________________________
AM-642 SCSI-to-Pertec Converter
The AM-642 is a family of interface units that connect an AMOS-based host system to a Pertec-
compatible ½" tape drive. The external version, Model AM-642-00, is mounted in a desktop chassis
and cabled to the host. Cabling arrangements are as follows:
•
With a Narrow SCSI AM-6060
—The AM-642-00 comes with a 3 ft. (0.9m), 50-conductor
cable. Plug the cable to the external 50-pin SCSI connector on a narrow SCSI AM-6060.
•
With a Wide SCSI AM-6060
—For a Wide SCSI AM-6060, order one of the following SCSI
cables to connect the AM-642 to the Wide SCSI external connector on the system chassis:
- PDB-00440-80 Cable, 50-pin Centronics to 68-pin External SCSI, 3 ft.
- PDB-00440-81 Cable, 50-pin Centronics to 68-pin External SCSI, 6 ft.
To use the
6 ft. cable, the system must be equipped with an AM-441-00
Wide SCSI Bus Repeater
.
An internally mounted version of the AM-642 is also manufactured, but is not installable in the
deskside chassis.