Service manual

Page 20 AM-6000 Service Manual
Rev. A02
X-Bus Cable Routing
You do not need to move either the AM-176 or the AM-319-20 board to mount new peripherals, which
means you won’t need to disconnect the X-Bus cables. However, if an X-Bus cable should come
unplugged from either the AM-176 or the AM-319-20 board it is extremely important that the cables are
plugged back in correctly. If the cables are not correct the system will not boot or run self test and one or
both boards could be seriously damaged!
The X-bus cables must be connected as follows:
C/S bus cable into P6 on the AM-176 board and P8 on the AM-319-20 board
A/D bus cable into P4 on the AM-176 board and P7 on the AM-319-20 board
ADDITIONAL DOCUMENTATION
Each peripheral device sold by Alpha Micro is covered by its own set of installation instructions. The
installation instructions include information on jumper settings, termination, and cabling. Before
installing a peripheral, make sure you read the documentation pertaining to the device.
If the documentation was not included with your peripheral device, it is probably contained on the
AlphaCD which is distributed to all Alpha Micro Value Added Resellers on a quarterly basis.