Owner`s manual

Page
8-4
Chapter Eight
AM-6000 Computer Owner's Manual, Rev. 00
Front Panel
Status Code
Description
35 Searching for the User File Directory (UFD) account [1,2] on first logical of
the primary boot device.
36 Searching for a BADBLK.SYS file on the first logical of the primary boot
device. Valid only on disk drives that use a BADBLK.SYS file.
37 Loading BADBLK.SYS on the first logical of the primary boot device.
Valid only on disk drives that use a BADBLK.SYS file
38 Searching for account [1,4] on the first logical of the primary boot device.
An error at this point may indicate disk problems. Try reloading the latest
version of the system software.
39 If you are
booting from the hard drive (DSK0)
, this code indicates the
computer is looking for the system monitor file in [1,4] as the primary boot
device. If this file is missing, reload the latest version of the system
software.
3A Loading the AMOS monitor from the primary boot device. If an error
occurs at this point, try reloading the latest version of the system software.
3b Beginning to execute the AMOS monitor from the primary boot device. If
an error occurs at this point, try reloading the latest version of the system
software.
3F Bootup failed because of an invalid primary boot device selection. Access
the CMOS setup routine by pressing Reset , then pressing the
ESC
key
when the code "CS" appears on the front panel. Verify the device and unit
number settings on the CMOS menu.
40 UPS inverter on. Normal operation recovering from an AC power failure.
Only displays if the UPS status cable is installed on the UPS port.
41 UPS is bypassed. System running without UPS battery protection. Please
turn on UPS run switch.
42 UPS inverter on, AC power failure detected, and the system is running off
batteries. This status is updated every second that the AC power is off..
43 Not valid, system inoperative.
44 UPS is on, and batteries are low. Batteries are recharging, please check.
45 UPS is bypassed and batteries are low.
46
UPS inverter is running and a low battery condition exists. Only
2 minutes
of power remaining!
System shutdown is imminent.
47 Not valid, system dead.
48 An internal fault has been detected in the UPS.
Front Panel Status Codes (continued)