Specifications

27
We reserve the right to modify technical specifications without prior notice.
UK830301/170306 © Alpha-InnoTec GmbH
NOTICE.
To remove the screen, release the snap-
in lugs in the reverse order, i.e. from top to
bottom, without the use of tools.
CAUTION.
The snap-in lugs have a tight t. Press rmly
from the side against the screen toward the
middle, so that the snap-in lugs do not break
off.
Installation of the room
thermostat for the cooling
function
This chapter is relevant for you only if you are using a heat
station with a model designator K.
CAUTION.
If oor heating systems are to be used for
cooling, the manufacturer must approve the
oor structure (especially the screed) for use
of the cooling function.
Use the room thermostat of the cooling function in a refe-
rence room as a reference variable. If the temperature in the
reference room falls below the set temperature, the cooling
function of the heat station will automatically shut off.
Operating manual of the heating and heat pump re-
gulator, “Cooling” chapter.
NOTICE.
You must install the room thermostat in
a reference room in addition to single-room
regulators.
You must install single-room regulators for swit
-
ching from heating to cooling (and vice versa).
NOTICE.
Always comply with the applicable local stan-
dards and directives.
Hot-water tank
The integrated hot water tank is enameled according to
DIN 4753 and is suitable for normal drinking water.