Specifications
20
We reserve the right to modify technical specifications without prior notice.
UK830301/170306 © Alpha-InnoTec GmbH
1 Connection for control unit
2 Connection for output
compressor 3PE
3 Connection for additional
heating 3NPE
4 N/PE
5 Only for units with cooling function:
3 additional terminals for room
thermostat and dew point sensor
6 Contactor for heating element
NOTICE.
Electric heating element is connected for
6 kW at factory. It can be connected for 2 or
4 kW on the contactor.
For further information, see the adhesive label on
the electric heating element.
1 Adhesive label on electric
heating element
After completion of all electrical installation work,
close the switch cabinet inside the unit.
Close the front panel of the unit if no further instal-
lation work inside the unit is to be performed im-
mediately.