Specifications
13
We reserve the right to modify technical specifications without prior notice.
UK830301/170306 © Alpha-InnoTec GmbH
installation of the hydraulic connections
CAUTION.
The heat source system must be designed
according to the specications of the heat
pump guide.
Heat pump guide and “Hydraulic connection”
instructions.
NOTICE.
Check to make sure that the diameters and
lengths of the pipes for the heating circuit
and the heat source are sufciently dimensi-
oned. The free compression of the circulating
pumps must be able to deliver at least the
minimum ow rate required for your model.
Overview “Technical data/scope of delivery”, “Heat
source” and “Heating circuit” sections.
DANGER!
Danger of fatal injury due to electric current!
Disconnect unit from power supply if it is
connected to the power supply!
Proceed as follows:
Install shut-off devices at the heating circuit.
Install shut-off devices at the heat source.
NOTICE.
During installation of the shut-off devices, the
evaporator and liqueer of the heat pump
can be rinsed, if necessary.
CAUTION!
The condenser may be rinsed only by custo-
mer service personnel authorized by the ma-
nufacturer.
CAUTION.
During connection of components, secure
connections on the module box and on the
compact unit against twisting in order to
prevent damage to the copper pipes in the
inside of the module box and the compact
unit.
CAUTION.
Once the module box has been placed in the
unit, it can no longer be transported.