Specifications
30
We reserve the right to modify technical specifications without prior notice.
83053100bUK © Alpha-InnoTec GmbH
Dismantling
DANGER!
Danger of fatal injury due to electric cur-
rent!
Electrical connections may be installed
only by qualied electricians.
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
DANGER!
Only qualied heating or cooling system
technicians are allowed to remove the unit
from the system.
CAUTION.
The anti-freeze mixture of the heat source must
not be allowed to enter the sewer system.
Collect anti-freeze mixture and dispose of prop-
erly.
DANGER!
Only qualied cooling system technicians
are allowed to dismantle the unit and its
components.
ATTE NTION
Recycle or provide for proper disposal of unit
components, refrigerants and oil in accordance
with the applicable regulations, standards and di-
rectives.
removal of the buffer battery
ATTE NTION
Before scrapping the heating and heat pump reg-
ulator, remove the buffer battery on the proces-
sor board. The battery can be removed using a
side cutter. Dispose of battery and electronic
components in keeping with environmental con-
siderations.
removal of the module box
Proceed as follows:
Remove insulation…
Close angle ball valves…
Attach service hoses from the extra box to the an-
gle ball valves…
Open bleeding valves of the angle ball valves using
a bleeding key and completely empty the module
box…
Disconnect hydraulic and electric connections…
Raise module box using the straps and lift and pull
from the unit.