Specifications
28
We reserve the right to modify technical specifications without prior notice.
83053100bUK © Alpha-InnoTec GmbH
Next, on the opposite side, moving upwards.
Lock the screen’s snap-in lugs in place in the slots
provided on the front of the facade…
Finally, press the screen’s upper snap-in lugs into
the slots provided on the front of the facade.
removing the screen
In order to remove the screen, the snap-in lugs must
rst be loosened by pressing one side completely
toward the middle of the screen. Thereafter,
remove the snap-in lugs from the opposite side.
Installation of the room
thermostat for the cooling
function
This chapter is relevant for you only if you are using a
heat station with a model designator K.
ATTE NTION
If oor heating systems are to be used for
cooling, the manufacturer must approve
the oor structure (especially the screed)
for use of the cooling function.
Use the room thermostat of the cooling function in a
reference room as a reference variable. If the tempera-
ture in the reference room falls below the set temper-
ature, the cooling function of the heat station will auto-
matically shut off.
Operating manual of the heating and heat pump
regulator, “Cooling” chapter.
NOTICE.
You must install the room thermostat in
a reference room in addition to single-
room regulators.
You must install single-room regulators for
switching from heating to cooling (and vice
versa).
NOTICE.
Always comply with the applicable local
standards and directives.
Hot-water tank
The integrated hot water tank is enameled according to
DIN 4753 and is suitable for normal drinking water.