Specifications
15
We reserve the right to modify technical specifications without prior notice.
83053100bUK © Alpha-InnoTec GmbH
connection of the vibration decouplers on
a unit without cooling function
Proceed as follows:
Arrange vibration decouplers in a quarter circle in
the unit to the connections on the module box…
Example of hose installation for connection on right
side of unit
A B
A Top view of outside of unit
B Top view of inside of unit
1 Heat source inow
2 Heat source outow
Example of hose installation for connection on left
side of unit:
A B
A Top view of outside of unit
B Top view of inside of unit
1 Heat source inow
2 Heat source outow
Screw included angle ball valves to vibration decou-
plers. Use seals from the extra box…
Screw angle ball valves to the connections provided
on the module box. Use seals from the extra box…
ATTE NTION
When tightening the connections on the module
box, always secure connections against twisting.
connection of the vibration decouplers on
a unit with cooling function
Proceed as follows:
Arrange vibration decouplers in a quarter circle in
the unit…
Example of hose installation for connection on right
side of unit:
A B
A Top view of outside of unit
B Top view of inside of unit
1 Heat source inow
2 Heat source outow
3 Connecting pipe to and from cooling
function for heat source inow
Example of hose installation for connection on left
side of unit:
A B
A op view of outside of unit
B Top view of inside of unit
1 Heat source inow
2 Heat source outow
3 Connecting pipe to and from cooling
function for heat source inow