Specifications

12
We reserve the right to modify technical specifications without prior notice.
83053100bUK © Alpha-InnoTec GmbH
installation of the module box
The entire cooling circuit of the heat station is contained
in the module box.
ATTE NTION
Do not tilt the module box more than a maxi-
mum of 45° (in any direction).
Proceed as follows:
Place module box in front of the unit…
1 Unit
2 Plug for electrical connection
3 Front edge of bottom of unit
4 Module box
Use straps to lift module box and initially place in
unit so that the rubber feet of the module box that
are facing the unit come to rest on the centering
plate behind the front edger of the bottom of the
unit…
Push module box into the unit until the front rub-
ber foot of the module box contacts the front edge
of the bottom of the unit and has to be lifted over
it…
When pushing in the box, make sure that the plugs
for the electrical connection are not pinched and
damaged.
Raise module box, push it further into the unit and
lower the box as soon as the rubber feet contact
the corresponding stops of the centering plate…
Set the front left rubber foot of the module box be-
tween the guide elements…
The module box is positioned correctly in the unit
when the rubber feed are placed as shown in the
following sketch:
1 Stops on centering plate
2 Rear rubber feet of module box
3 Centering plate for module
box on bottom of unit
4 Front rubber foot of module box
5 Guide element
ATTE NTION
Once the module box has been placed in
the unit, it can no longer be transported.
installation of the hydraulic connections
ATTE NTION
The heat source system must be designed ac-
cording to the specications of the heat pump
guide.
Heat pump guide and “Hydraulic connection”
instructions.
NOTICE.
Check to make sure that the diameters and
lengths of the pipes for the heating circuit and
the heat source are sufciently dimensioned.
The free compression of the circulating pumps
must be able to deliver at least the minimum
ow rate required for your model.