Specifications

25
We reserve the right to modify technical specifications without prior notice.
UK830300/170717 © Alpha-InnoTec GmbH
Gerätebezeichnung
Heat pump type Brine/water ı Air/water ı Water/water • applicable ı — not applicable
Installation location Indoors ı Outdoors • applicable ı — not applicable
Conformity CE
Performance data Heating capacity/COP at
B0/W35 Standard point acc. to EN14511
2 condensers
1 condensers
kW ı …
kW ı …
B0/W45 Standard point acc. to EN14511 kW ı …
B0/W35 Standard point acc. to EN255
2 condensers
1 condensers
kW ı …
kW ı …
Limits of application Heating circuit °C
Heat source °C
Additional operating points
Sound Sound level measured at distance of 1m around the device (in reverberating room) dB(A)
Sound power level according to EN12102 dB
Heat source Volume ow: minimum ow rate ı nominal ow rate ı maximum ow rate l/h
Pressure loss heat pump ∆p (with cooling ∆pK) ı volume ow bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı volume ow bar (bar) ı l/h
Anti-freeze agent monoethylene glycol
minimum concentration ı frost proof down to % ı °C
Heating circuit Volume ow: minimum ow rate ı nominal ow rate ı maximum ow rate l/h
Pressure loss heat pump ∆p (with cooling ∆pK) ı volume ow bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı volume ow bar (bar) ı l/h
General unit data Dimensions (see dimensional drawing for the specied unit size) unit size
Total weight (including cooling) kg (kg)
Additional weight module 1 kg
Additional weight module 2 kg
Connections Heating circuit
Heat source
Refrigerant Refrigerant type ı Quantity … ı kg
Electric Voltage code ı all-pole circuit breaker heat pump *) … ı A
Voltage code ı circuit breaker control voltage *) … ı A
Voltage code ı circuit breaker electric heating element *) ı A
Heat Pump Effective power consumption in standard point B0/W35 according to EN14511: Power consumption ı current consumption ı cosφ kW ı A ı …
Maximum device current within the limits of application A
Starting current: direct ı with soft starter A ı A
Protection type IP
Output electric heating element 3 ı 2 ı 1 phase kW ı kW ı kW
Components Circulating pump heating circuit at nominal ow rate: Power consumption ı current consumption kW ı A
Circulating pump heat source at nominal ow rate: Power consumption ı current consumption kW ı A
Passive cooling function only for units with designator K: Cooling output at nominal volume ow (15 °C heat source, 25 °C heating water) kW
Safety equipment Safety component heating circuit ı Safety component heat source scope of delivery: • yes — no
Heating and heat pump regulator scope of delivery: • yes — no
Electronic soft starter integrated: • yes — no
Expansion vessels Heat source: Scope of delivery ı Volume ı Initial pressure • yes — no ı l ı bar
Heating circuit: Scope of delivery ı Volume ı Initial pressure • yes — no ı l ı bar
Overow valve integrated: • yes — no
Vibration decouplers Heating circuit ı heat source scope of delivery: • yes — no
UK813196
*) comply with local regulations n.n. = not detectable
SWC 80H(/K)
• ı — ı
• ı
8,9 ı 4,5
9,1 ı 4,7
20 – 65
-5 – 25
40
53
1450 ı 1900 ı 4000
— ı
0,68 (0,66) ı 1450
25 ı -13
800 ı 1500 ı 1900
— ı
0,41 (0,40) ı 1100
1
203 (218)
G1"AG
G1"AG
R407c ı 2,1
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
1,98 ı 3,7 ı 0,78
5,9
30 ı
20
6 ı 4 ı 2
0,08 ı n.n.
0,2 ı n.n.
6,9
• ı
• ı 12 ı 0,5
• ı 25 ı 1,5
• ı
813170-a
SWC 100H(/K)
• ı — ı
• ı
10,2 ı 4,6
10,3 ı 4,7
20 – 65
-5 – 25
40
53
1600 ı 2200 ı 3500
— ı
0,53 (0,50) ı 1600
25 ı -13
900 ı 1800 ı 2200
— ı
0,34 (0,33) ı 1300
1
206 (221)
G1"AG
G1"AG
R407c ı 2,2
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
2,22 ı 4,1 ı 0,78
6,9
— ı 20
20
6 ı 4 ı 2
0,08 ı n.n.
0,2 ı n.n.
8,3
• ı
• ı 12 ı 0,5
• ı 25 ı 1,5
• ı
813171-a
SWC 120H(/K)
• ı — ı
• ı
11,7 ı 4,5
11,9 ı 4,7
20 – 62
-5 – 25
B–2 ı W65
40
53
1800 ı 2600 ı 3900
— ı
0,51 (0,49) ı 2050
25 ı -13
1000 ı 2000 ı 2400
— ı
0,32 (0,30) ı 1450
1
209 (224)
G1¼"AG
G1¼"AG
R407c ı 2,9
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
2,6 ı 4,8 ı 0,78
7,5
— ı 25
20
6 ı 4 ı 2
0,08 ı n.n.
0,2 ı n.n.
10,2
• ı
• ı 18 ı 0,5
• ı 25 ı 1,5
• ı
813172-a
SWC 60H(/K)
• ı — ı
• ı
5,7 ı 4,4
5,8 ı 4,7
20 – 65
-5 – 25
40
53
1000 ı 1400 ı 2500
— ı
0,52 (0,5) ı 1100
25 ı -13
500 ı 950 ı 1400
— ı
0,46 (0,45) ı 700
1
200 (214)
G1"AG
G1"AG
R407c ı 1,8
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
1,29 ı 2,4 ı 0,78
4,0
27,4 ı —
20
6 ı 4 ı 2
0,08 ı n.n.
0,1 ı n.n.
3,7
• ı
• ı 12 ı 0,5
• ı 25 ı 1,5
• ı
813169-a
SWC 70H(/K)
• ı — ı
• ı
6,9 ı 4,4
7,0 ı 4,5
20 – 65
-5 – 25
40
53
1250 ı 1650 ı 2500
— ı
0,48 (0,46) ı 1250
25 ı -13
600 ı 1200 ı 1500
— ı
0,47 (0,46) ı 850
1
202 (216)
G1“AG
G1“AG
R407c ı 2,0
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
1,57 ı 3,1 ı 0,73
5,0
29 ı
20
6 ı 4 ı 2
0,08 ı n.n.
0,2 ı n.n.
5,3
• ı
• ı 12 ı 0,5
• ı 25 ı 1,5
• ı
813190