Specifications

37
-F1
230V/6,3A
3
-Trafo/Primär
230VAC
9
-Trafo/sekundär
24VAC
16
-X100
1
-X101
Dew-point sensor
4
10
17
2
18
5
19
4
1/N 230VAC
power supplypower supply
Contactor, secondary pump
A10
T
ZW3
Comfort board
MA3
TSK
GND
TB3
RF3
Transformer 230/24VAC
RT
K-SP
Control signal, additional heat generator 3
Series fuse mixer circuit pump 2 max. 230V 6.3A potential-free contact
Name
L
MA3/MZ3
Pump for mixing circuit 3
TSS
SWT
A6
Charge/discharge/cooling mixer
SUP
GND
TSK
FP3
MA2
RF2
FP2
F1
FP3
A02
A6
TSS
TB3
SLP
Legend:
UK831163
TEE
AIn
GND
FP2
SUP
A01
A01
GND
RF2
Plug, Luxtronik
SLP
GND
GND
GND
L
K-SP
Solar charge pump
Error solar tank
TB2
SLP
TB3
Error solar collector
TEE
TSK
Analogue output 1 0-10V
SUP
Function
230V
FP2
Pump, mixing circuit 2, dry contact
MZ3
Accessory connections dew-point detectorX100
Analogue input 0-10V / 0-20 mA
X101
RT
Room thermostat
Connections, dew-point detector
M
Room station, mixing circuit 3
Sensor mixing circuit 3
TSS
-A10
Sensor, external energy source
TB2
Swimming pool, thermostat
Cooler sensor separator storage
MA3/MZ3
SWT
A02
RF2
RF3
Room station, mixing circuit 2
GND
ZW3
Comfort board, reversible
Plug, Luxtronik
Swimming pool, circulating pump
GND
ZW3
RF3
FP3
AIn
GND
TB2
SWT
A01
TEE
MZ2
AIn
Analogue output 2 0-10V
FP2
A02
10.06.2009
Reversibel
Achim Pfleger
1/1
Comfort board LUX2
831163
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
22.10.2009
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
-
A. Pfleger
ÄM
Zustand
Index:
Bl von AnzÄnderung
Urspr.
Blatt-Nr.
Bearb.
Datum
Name
Norm
Ers. für
Projekt:
Gepr.
ANr.
Ers. durch
Datum
We reserve the right to modify technical specifications without prior notice.
83051400aUK © Alpha-InnoTec GmbH
CAUTION:
For all unit-specic connections, refer to the terminal
diagram for the respective unit.
Operating manual for the respective unit
Terminal diagram Comfort board