3.11 GPI
Option G must be installed. The settings of this submenu are used for operation with a relay
which may be triggered at a programmed time. A “GPI“ (General Purpose Interface) is a
switching relay. The contacts between COM1and NO1 are normally open, or closed when
triggered, and normally closed between COM1and NC1, or open when triggered,
respectively. Switching is performed pulse-like after triggering. The pulse, i.e. trigger duration
is adjustable between about 64 ms - 1.28 s (+0 / -20 ms). Triggering is performed, when the
GPI is active and a pre-set comparative time information value is detected by the LTC
generator or one of the timer times out of A, B, C, D, E or F.
SET TIME
Pre-set the comparative time value for GPI relay switching.
GPI
SET MODE
Set the GPI mode.
3.11.1 SET TIME: Pre-set the Comparative Time Value for Relay Switching
Press the enter button to display or change the current setting. The flashing pair of digits can
be changed using the
or button, the next pair of digits can be selected using the
button. The range of values 00-23 is for the hours, 00-59 for the minutes and seconds. The
frames are assumed to be 00. Press the enter button to confirm your choice and to quit the
menu.
3.11.2 SET MODE: Set the GPI Mode
Press the enter button to display or change the current parameters. The flashing field can be
changed using the
or button, the next field can be selected using the button. Press the
enter button to confirm your choice and to quit the menu.
Digit 8
Digit 7
Digit 6 Digit 5 Digit 4 Digit 3 Digit 2
Digit 1
Trigger
L, A...F
Pulse
0 ... 9
on /off
Trigger
L Trigger using the time information of the generated LTC.
A (B, C, D, E, F) Trigger using timer time A or B or C or D or E or F.
Pulse
0 ... 9 Set the trigger pulse duration: 0 = 128 ms, 1 = 256 ms, ..., 9 = 1280 ms (accuracy:
+0 ms, -64 ms).
on/off
off Function not active.
on Function active.