Technical data
Installation & Operation Manual GM-TTT
Page 52
3.11 GPI
Option G must be installed. The settings of this submenu are used for operation with a relay
which may be triggered at a programmed time. A “GPI“ (General Purpose Interface) is a
switching relay. The contacts between COM1and NO1 are normally open, or closed when
triggered, and normally closed between COM1and NC1, or open when triggered,
respectively. Switching is performed pulse-like after triggering. The pulse, i.e. trigger duration
is adjustable between about 64 ms - 1.28 s (+0 / -20 ms). Triggering is performed, when the
GPI is active and a pre-set comparative time information value is detected by the LTC
generator or one of the timer times out of A, B, C, D, E or F.
SET TIME
Pre-set the comparative time value for GPI relay switching.
GPI
SET MODE
Set the GPI mode.
3.11.1 SET TIME: Pre-set the Comparative Time Value for Relay Switching
Press the enter button to display or change the current setting. The flashing pair of digits can
be changed using the
↑ or ↓ button, the next pair of digits can be selected using the →
button. The range of values 00-23 is for the hours, 00-59 for the minutes and seconds. The
frames are assumed to be 00. Press the enter button to confirm your choice and to quit the
menu.
3.11.2 SET MODE: Set the GPI Mode
Press the enter button to display or change the current parameters. The flashing field can be
changed using the
↑ or ↓ button, the next field can be selected using the → button. Press the
enter button to confirm your choice and to quit the menu.
Digit 8
Digit 7
Digit 6 Digit 5 Digit 4 Digit 3 Digit 2
Digit 1
Trigger
L, A...F
Pulse
0 ... 9
on /off
Trigger
L Trigger using the time information of the generated LTC.
A (B, C, D, E, F) Trigger using timer time A or B or C or D or E or F.
Pulse
0 ... 9 Set the trigger pulse duration: 0 = 128 ms, 1 = 256 ms, ..., 9 = 1280 ms (accuracy:
+0 ms, -64 ms).
on/off
off Function not active.
on Function active.