Technical data
Installation & Operation Manual GM-TTT
Page 50
3.10 LTC IN
Option L must be installed. This submenu permits to make the settings for the tc operating
mode (Jam-Sync applications) and for the VTR LTC (if LTC(MTD) is generated). The data of the
readout LTC may be switched to the display for test purposes.
MODE
Settings for the operation mode using external LTC.
OFFSET
Offset programming for the time information.
1 (data)
Indication of the readout LTC time.
2 (data)
Indication of the binary groups of the readout LTC.
LTC IN
3 (data)
Indication of the current six flag bits of the readout LTC.
3.10.1 MODE: Settings for the Operation Mode Using External LTC
Press the enter button to display or change the current parameters. The flashing field can be
changed using the
↑ or ↓ button, the next field can be selected using the → button. Press the
enter button to confirm your choice and to quit the menu.
Digit 8
Digit 7 Digit 6 Digit 5
Digit 4
Digit 3 Digit 2
Digit 1
Time/User
TU, T-, U-, tu
Cont
1, Co, 00
08, 16, 32, 64
Stand-By
-, S
Offset
-, o
Sync
-, L
Time/User: Adopt the time information and/or binary groups (tc operating mode)
T U Time and binary groups.
T - Only time.
- U Only binary groups.
t u The readout LTC time is transferred to the binary groups of the generated time code
(cross Jam-Sync).
Cont: Set continuous transfer or transfer with stop (tc operating mode)
1 1x Jam-Sync: The data are transferred once, then the tc operating mode is auto-
matically deactivated, and the start operating mode is switched on.
Co Continuous Jam-Sync: In this mode, the generator continues to count by itself, if no
LTC can be read out (unlimited flywheel).
00 Jam-Sync with stop: If no LTC is read out and time transfer is selected, the generator
will stop.
08 ... 64 Jam-Sync with “flywheel": If no LTC is read out and time transfer is selected, the
generator will continue to count by a specified number of frames (adjustable
flywheel), before it stops.