Technical data

Installation & Operation Manual GM-TTT
Page 49
3.9 SERIAL
The settings of this submenu are provided for an optional remote control of the GM-TTT. The
standard unit is equipped with a RS485 serial interface with fixed format and protocol.
FORMAT
Select the baud rate and format of the serial interface
(option).
SERIAL
PROTOCOL
Select the remote control protocol (option).
3.9.1 FORMAT: Select the Baud Rate and Format of the Serial Interface
Press the enter button to display or change the current parameters. The flashing field can be
changed using the
or button, the next field can be selected using the button. Press the
enter button to confirm your choice and to quit the menu.
Digit 8
Digit 7 Digit 6
Digit 5 Digit 4 Digit 3 Digit 2
Digit 1
Par.
0,1,E,o,n
Baud Rate
19 2, 9 6, 4 8, 2 4
Baud rate
19 2 19 200 bps.
9 6 9 600 bps.
4 8 4 800 bps.
2 4 2 400 bps.
Parity
0 The parity bit is fixed to 0.
1 The parity bit is fixed to 1.
E Even parity.
o Odd parity.
n No parity bit.
Digit 1 shows the number of data bits (= 8, fixed setting).
The number of stop bits is fixed = 1.
3.9.2 PROTOCOL: Select the Remote Control Protocol
This function is optional and not used in the standard version. The standard protocol used for
option 2 (RS232) or option 4 (RS422) is described in the chapter entitled “Serial Remote
Control Interface“.