Technical data
Installation & Operation Manual GM-TTT
Page 35
30 Frame rate = 30 frames per second. 30 frames exactly give one second of real time
(at genlock to internal reference). The LED 30 flashes slowly. With this frame rate the
unit sets internal parameters according to the 525/60 television system, concerning
the VITC generator, the video/black-burst genlock and some time code flag bits.
30dr Frame rate = 30 frames with drop-frame compensation, used in a 525/60 television
system. The LED 30 lights up. With this frame rate the unit sets internal parameters
according to the 525/60 television system, concerning the VITC generator, the
video/black-burst genlock and some time code flag bits.
3.2.8 PARA: More System Parameters
Adjust various system parameters. Press the enter button to display or select the genlock mode
of the LTC output. The flashing field can be changed using the
↑ or ↓ button, the next field
can be selected using the
→ button. Press the enter button to confirm your choice and to quit
the menu.
Digit 8
Digit 7 Digit 6
Digit 5 Digit 4 Digit 3 Digit 2
Digit 1
START
START: Switches on/off the START function:
o: off, i.e. button start pressed during main operating mode start has no function.
A: START function activated, i.e. button start pressed during main operating mode
start transfers the time value which has last been chosen as a start value (menu
SET - START) to the LTC time information, and the generator keeps on counting
continuously from this start value on.
3.2.9 FACTORY: Factory Reset
Force a new start of GM-TTT with all parameters set to a default setting (see chapter “Factory
Settings”). After a first press at the enter button the display shows ‘RESET ==’. This mode will
be skipped if now the menu,
↑, ↓ or → button is pressed. A further press at the enter button
will execute the RESET.