Technical data

Installation & Operation Manual GM-TTT
Page 30
3.2.2 SET USER: Enter User Defined Data for the Binary Groups
Press the enter button to enable the pre-set of user defined data for the binary groups of the
time code. The last pre-set value appears at the display. The value of the flashing digit can be
changed using the
or button, the next digit can be selected using the button. The
allowed range will be 0-9 and A-F, i.e. a hexadecimal value. Press the enter button to store
the values and to quit the menu.
Digit 8
Digit 7 Digit 6
Digit 5 Digit 4 Digit 3 Digit 2
Digit 1
BG8
BG7 BG6 BG5 BG4 BG3 BG2 BG1
It depends on the setting of the USER MODE (at menu SET - ... - USER MOD) and - if the tc
operating mode selected - on the setting at menu LTC IN - MODE, whether the user defined
data appear at the LTC output:
tc operating mode is not selected:
USER MODE = 0 SET: the binary groups of the time code get all the user defined data.
USER MODE = 2 DATE: binary groups 1 to 6 are reserved for day, month and year of the
internal clock. Only binary groups 7 and 8 correspond to the two most significant digits of
the pre-set values.
With all other settings of USER MODE the binary groups are reserved for other functions.
tc operating mode is selected:
If at LTC IN - MODE any mode is selected, which transfers data into the binary groups of
the time code generator, then this feature overwrites any other user defined data of the
time code output.
If only a data transfer to the time addresses has been selected, then the same applies as
described at “tc operating mode is not selected” above.
3.2.3 SET TIME: Set the Time of the Internal Clock
Press the enter button to enable the pre-set of the time of the internal clock. The value of the
flashing pair of digits can be changed using the
or button, the next pair can be selected
using the
button. The allowed range will be 00-23 of the hours, 00-59 of the minutes and
seconds. Press the enter button to transfer the values to the internal clock and to quit the
menu.
With option T or GPS IN the time of the built-in reference is set at the same time.
Usually the time of the internal clock will be set automatically by an external reference.
3.2.4 SET DATE: Set the Date of the Internal Clock
Press the enter button to enable the pre-set of the date of the internal clock. The current value
appears at the display, in the format day/month/year at the place of minutes/seconds/frames.
The value of the flashing pair of digits can be changed using the
or button, the next pair
can be selected using the
button. Pressing the enter button the unit checks the input for a
valid date, then the values will be transferred to the internal clock.
With option T or GPS IN the date of the built-in reference is set at the same time.
Usually the date of the internal clock will be set automatically by an external reference.