Technical data
Installation & Operation Manual GM-TTT
Page 29
3 Detailed Menu Description
3.1 General Description
The menu lets you adjust parameters or pre-set values, or it shows test and status data. The
menu button switches on or off the menu. With
↑ and ↓ buttons you will go to the various
submenus, with the
→ button you reach all the items present at this submenu. Chapter 1.7
gives an overview of the menu structure. The enter button executes functions, starts set modes
or stores settings.
Pressing the menu button to switch the menu off the display will return to show the time or
binary groups data. Pressing this button during a set mode will quit this mode and no new
setting will be stored. Same applies if the time/user button is pressed.
If there has been a change to any setting GM-TTT stores the new data into the non-volatile
memory. The display shows “store” and no key stroke will be acknowledged during that time.
3.2 SET
SET START
Enter a start value of the time code generator.
SET USER
Enter user defined data for the binary groups of the time
code.
SET TIME
Set the time of the internal clock.
SET DATE
Set the date of the internal clock.
USER MOD.
Select what kind of information should appear in the binary
groups.
LOCK
Select the genlock and the colour lock mode.
F-RATE
Select frame rate and television system.
PARA
More system parameters.
SET
FACTORY
Factory reset, all current parameters except ‘user area’ and
‘time zone parameters’ can be reset to default values.
3.2.1 SET START: Enter a Start Value
Press the enter button to enable the pre-set of a start value (referred to the time address of the
time code). The last pre-set value appears at the display. The values of the flashing pair of
digits can be changed using the
↑ or ↓ button, the next pair can be selected using the →
button. The allowed range will be 00-23 of the hours, 00-59 of the minutes and seconds, 00-
23/24/29 of the frames - dependent on the frame rate. Press the enter button to store the
values and to quit the menu.
Whenever the start button is pressed in the start operating mode and the START function is
enabled (submenu SET - ... - PARA), the generator starts its free-running counter with this start
value.