Technical data

Installation & Operation Manual GM-TTT
Page 28
2.5 Start Operating Mode
Free-running counter operating mode: when this mode is initiated by the start button, the unit
simply switches to a free-running counter mode internally.
Pressing this button during start operating mode and having the START function enabled (at
submenu SET - ... - PARA): the time value which has last been chosen as a start value (menu
SET - START) will be transferred to the time addresses of the LTC output, and the generator
keeps on counting continuously from this start value on.
LTC output frequency
1
st
preference: If the unit works within a television system, choose genlock to a black-burst
or video signal (select genlock = bb at menu SET - ... - LOCK and press genlock button).
2
nd
preference: With a stable external LTC signal (not a VTR LTC) choose genlock to LTC
(select genlock = LTC at menu SET - ... - LOCK and press genlock button).
3
rd
preference: Press intern button to select the internal reference.
Internal clock, time/date handling
The internal clock get a pre-set from a built-in or external real time reference. The mode of
operating with the reference time input is selected at menu REFER - MODE1 and MODE2.
Time zone programming is done at submenu ZONE (select the offset and the Daylight
Saving Times).
If any time and/or date applications should be kept during the start operating mode, the
LTC output frequency should be locked to a stable reference, because this is the frequency
of the internal clock as well. The internal clock can be programmed to get a time and date
update every second (menu REFER - MODE 1), in that case the internal clock follows the
reference time mostly independent from the LTC output frequency. The binary groups of
the LTC output may contain time and/or date, as selected at menu SET - ... - USER MOD,
for example the date (different formats) or the time and date of the LTC(MTD) format for
use in the MTD system.
Time code information: time address
Free-running counter, starts with the values selected at menu SET - START (if enable at
menu SET - ... - PARA).
Time code information: binary groups
As selected at menu SET - ... - USER MOD.