Sentinel HDi120 C AlorAir Solutions INC. Add: 4240 Latham Street, Suite D, Riverside, CA 92501 Tel: 888-990-7469 E-mail: sales@alorair.com Specifications subject to change without notice.
Important Notes TableofContents ·Always connect your dehumidifier using a grounded electrical connection ImportantNotes ............................................. 2 WarrantyRegistration ......................................2 Specifications..................................................3 HowitWorks ................................................ 3 InstallationRequirements ................................ 3 Installation ......................................................
Installation Specifications Capacity @ 80°F/60%RH: 120 Pints Per Day Capacity @ 73°F/60%RH: 93 PPD Airflow: 290 CFM Operating Temp. Range: 33.8-104°F Operating Relative Humidity Range: 35%-90% COP: 2.7 L/kWh Refrigerant: R410A Amperage Usage: 7.8 Amps Power Supply: 115V/60Hz/Single Phase Outlet Requirement: 15 Amp, 3 prong, GFCI Sound Level: 60 dBa Dimensions LxWxH: 23.8” x 14.7” x 17.9” ETL Listed: Yes 1. Place dehumidifier on a level surface. • Do not place unit directly on vapor barrier.
·The continuous light will illuminate green and the display will show “CO”. ·To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%. Remote Control Instructions AlorAir Dehumidifiers can be controlled using an optional remote accessory. The remote connects to your dehumidifier via a 25’ CAT 5 cable, with the integrated sensor giving you multiple options for monitoring surrounding conditions. 4.
Operating Instructions Unit Diagram 1. Start the machine • Press the power key to turn the dehumidfier on. 2. Adjust the settings • Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%) Control Panel Handle 3. Stop the machine Side Panel • Press the power button again and the dehumidifier will stop. Note that the fan will continue to operate for 1 minute after the unit has shut off. DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP. Pre-filter 4.
Maintenance Removing the Pump **For more detailed instructions, visit www.alorair.com** WARNING: Always unplug the unit before doing any maintenance. Cleaning the Machine Body ·Use a soft, damp cloth to clean the exterior of unit. Do not use any soap or solvents 1. Remove the 9 screws on the side panel and set panel aside. 2. Remove the screw holding the pump in place. 3. Undo the 3 pump electrical quick connects and 1 drain quick connect. 4.
Dehumidifier Storage If the unit will be stored for an extended period of time, complete the following steps: 1. Turn off the unit and allow it to dry. 2. Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir. 3. Wrap and secure the power cord. 4. Cover the filter mesh. 5. Store in a clean, dry space.
Limited Warranty Spare Parts All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
Limited Warranty Exclusions EXCLUSIONS: DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY 1. ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO: ● FLOODING ● FIRE ● WATER DAMAGE ● HURRICANE STORM DAMAGE 2. IMPROPERUSAGE-INCLUDING BUT NOT LIMITED TO: ● POOL/SPA/TUB APPLICATIONS ● MISUSE, ABUSE OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL ● IMPROPER INSTALLATION OR DESIGN ● MPROPER VOLTAGE ● LACK OF NORMAL CARE ● FAILURE TO FOLLOW INSTRUCTIONS 3. CORROSION 4. FREEZING 5.