Instructions / Assembly

TEMPERATURE SENSOR PLACEMENT
Mountthesensorhousing(themetalcomponentziptiedtotheelementsinstep1)vertically,atleast18”tothesideoftheheater
and18”belowthehighestpointofthesauna.Ifitistoohighonthewallortooclosetotheheater,itwillsensethatthesaunais
hotterthanitactuallyis,triggeringaprematureshuto(23).
Placethesensorpininthehousingwiththebulbuprightandclosethewingsofthehousingoverthesensorpin(24,25).
Concealthesensorhousingandpinwiththesensorcoverandprovidedscrew(26).
Concealthesensorwirewiththegroovedtrimpiecesfromstep1(27).Youwilllikelyhavetocutseveraltrimpiecestotthedistance
betweenyourheaterandthesensorpin.Mountthemwiththescrewsprovidedinthehardwarebaggieyouremovedinstep1.
INSTALLING THE HEATER GUARD
YourKIPheatercomeswithacedarheaterguard.Usetheprovidedhardwaretoassemblethefencecomponentstogether(28-31),and
secureittothewallsothatitevenlysurroundstheheater(32).Itshouldbepositionednohigherthantheexposedsaunastones.
KIP HEATER INSTALLATION MANUAL
page 6
Image24 Image25Image26
Image23
Image28 Image29Image30Image31Image32
18
18
Image27