4.3 Wall Mount
Note: For wall mount installations, discard included power cord and use only a UL listed power cord of type
SJ or SO or better.
To mount the Allworx 48x on ½” drywall:
1. Verify that there is sufficient clearance around the server’s front and rear panels to allow power, network,
and telephony connections. Place the brackets on each side of the unit so that the smaller face of the L-
Bracket is facing down (See Figure 4).
2. Install the mounting brackets on each side of the server chassis using the four 6-32 flat head screws.
3. Use 50lb self-drilling drywall anchors rated for at least 20 lbs with screws that are either #6 or #8. Locate
two anchors that will support the upper end of the unit using the wall mount diagram. Install the anchors
per the anchor manufacturer’s recommendation. Install the mounting screws through the bracket holes
and into the anchors.
4. Tighten screws so that Allworx server is secured firmly against the wall.
Caution: The Allworx server must be securely mounted to the wall to avoid equipment damage or
personal injury.
Note: The unit must be mounted with the front facing left or right, not up or down (See Figure 5).
Figure 4: Wall Mount Bracket Installation