Allworx 10x Installation Guide
-PAGE INTENTIALLY LEFT BLANK-
10x Installation Guide Table of Contents 1 2 3 4 Installation Overview.....................................................................................................................................1 Unpacking .....................................................................................................................................................2 Chassis Views...................................................................................................................................
10x Installation Guide 1 Installation Overview Installation of the Allworx® 10x involves the following steps: 1. Unpacking 2. Mechanical Installation 3. Electrical Installation 4. Accessories Installation 5. Telephony Installation 6. Server Configuration 7. Network Installation Each of these steps will be described in the following sections. 300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com © 2007 InSciTek Microsystems, Inc. All rights reserved.
10x Installation Guide 2 Unpacking Open the box and carefully unpack it. Save all shipping and packaging materials. Verify all items against the parts list shown in Table 1. If any items are missing, contact your dealer or Allworx Customer Support at 866255-9679 - press 3.
10x Installation Guide 3 Chassis Views Figure 1: Front Chassis View 7 3 1 2 4 5 8 9 10 6 1 Power switch Press & Release – Normal shutdown within a few seconds Press & Hold – Forced shutdown 2 Front panel LEDs. Power – Indicates system start up activity Drive – Indicates drive activity Alert – Indicates drive or other system fault condition 3 RJ-45 10BaseT/100BaseTX Auto-Sensing Auto-MDI/MDIX switched Local Area Network Ethernet ports.
10x Installation Guide Figure 2: Rear Chassis View 11 15 13 12 14 11 Exhaust fan cover 12 Power cord connector 13 Voltage selection switch 14 Permanent ground connecting screw 15 Air intake and exhaust vents 300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com © 2007 InSciTek Microsystems, Inc. All rights reserved. Allworx is a registered trademark of InSciTek Microsystems.
10x Installation Guide 4 Mechanical 4.1 Tabletop or Shelf Placement To install the Allworx 10x on a tabletop or shelf: 1. Remove the four rubber feet from the Accessory Kit. 2. Turn over the chassis and notice the circles on each corner. 3. Remove the paper backing from each rubber foot and place one foot in each circle. 4.2 Rack Mount To install the Allworx 10x in a standard 19-inch equipment rack: 1. Remove the two brackets and associated screws from the Accessory Kit. 2.
10x Installation Guide 3. Place the brackets so that the smaller faces extend away from the bottom of the unit as shown in Figure 4. Figure 4: Wall Mount Bracket Installation 4. Install the mounting brackets on each side of the chassis using four 8-32 flat head screws. 5. Secure the unit to the wall using appropriate hardware. Caution: The Allworx server must be securely mounted to the wall to avoid equipment damage or personal injury.
x Installation Guide 5 Electrical 5.1 Chassis Ground and Voltage Selection Connect the chassis to earth ground using 18 AWG (or larger) wire from the chassis ground screw located next to the power receptacle on the rear panel as shown in Figure 5. Ground connecting screw Voltage setting switch Figure 5: Ground Connection and Voltage Selection Be sure the voltage switch on the rear of the unit is set to the appropriate setting for your location.
10x Installation Guide 6 Accessories 6.1 Music-On-Hold Connect the output from your music system to the server using a 3.5mm stereo plug line-in audio adapter cable. Insert the male cable end into the audio connector labeled “In” on the front panel. Only the audio channel associated with the tip of the plug is used. 6.2 Overhead Paging Connect the server to the input of your paging system using a 3.5mm stereo plug audio cable.
10x Installation Guide 7 Telephony 7.1 Analog Caution: To reduce the risk of fire, use only 26 AWG (or larger) UL listed or CSA certified telecommunications line cord. The server’s analog phone connections can be used to connect Central Office (CO) lines, Direct Inward Dial (DID) lines, or telephone handsets. Table 3 describes the ports. RJ-11 Ports Type 1-3 FXO (loop-start) 4-9 FXO (loop-start) or FXS 10-16 FXS Description Used to connect to Central Office (CO) lines.
10x Installation Guide 8 Server Configuration The Allworx 10x provides an administrative interface to configure and administer the server. The administrative interface is accessed using a web browser. Assuming the network settings are set to their factory defaults, the steps to connect to this interface are: 1. Plug your PC into one of the server’s LAN ports. 2. Set up the PC’s network interface to obtain an IP address automatically (using DHCP). 3.
10x Installation Guide 9 Data Network The Local Area Network (LAN) and Wide Area Network (WAN) data network ports are 10BaseT/100BaseTX auto-sensing and auto-MDI/MDIX ports. The Allworx 10x is a sophisticated network appliance that must be properly configured before being connected to the LAN and WAN. Note: Do not plug any network cables into the server without first properly configuring the server.
10x Installation Guide 10 Configuration Example “Unlimited” number of SIP phones SIP Phone 10/100 E-net SIP Phone 10/100 E-net SIP Phone Network Device 10/100 E-net 10/100 E-net E-net Switch or Hub E-net Switch or Hub Network Printer Paging Amplifier 10/100 E-net 10/100 E-net LAN WAN 10/100 E-net 10/100 E-net Network Server Music on Hold Source Allworx 10x Server DSL or Cable Modem 10/100 E-net Line level audio input Line level audio output In Up to 13 outside DID lines* PSTN Centra
10x Installation Guide 11 Physical and Environmental Specifications Dimensions (W x H x D) Weight (Base Model) Power Temperature Humidity 17.5 x 15 x 3.5 inches (44.5 x 38 x 9 cm) 17 lbs AC 100-127/200-240V, 4/2A, 47-63Hz 0° ~ 40° C 15% ~ 90% RH, Non-condensing 300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com © 2007 InSciTek Microsystems, Inc. All rights reserved. Allworx is a registered trademark of InSciTek Microsystems.
10x Installation Guide 12 Regulatory Notices 12.1 FCC Part 68 This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the back side of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, provide this number to the telephone company.
10x Installation Guide Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
10x Installation Guide You may also find helpful the following booklet, prepared by the FCC: "How to Identify and Resolve Radio-TV Interference Problems." This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402. Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commissions rules.