User`s guide

System Administrator’s Guide – Release 7.2.3.x
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other names may be trademarks or registered
trademarks of their respective owners.
Revised: September 1, 2010
Page 133
DID blocks and routes plans and digital lines do not appear on the Import Configuration screen. These
settings will always be imported when included on the export.
Digital line fields PPP Username, PPP Password and PPP MTU are not include in the export.
If the current system is not “clean” and has conflicts with the imported configuration settings, then
conflicts will be resolved for the import settings in the following manner:
- Digits will be appended to user login names and incremented, starting at 01, as needed (e.g.
jAdams will become jAdams01)
- Extensions will be changed to the lowest available extension
- Phones with conflicting MAC addresses will not be imported and all references will be removed
(e.g. call routing and BLF PFK assignments)
- Analog phones with no available port will not be imported and all references will be removed (e.g.
call routing and BLF PFK assignments)
SIP handsets and SIP gateway station numbers may not be preserved on an import. If station numbers
are changed for generic SIP phones or SIP gateways, then the new station number must be set up on
each device.
On Multi-site configurations, the Export will not include references to extensions, users or outside lines
at remote sites.
Imported extensions/users are limited to the total number available in the imported system. The
available extensions/users are determined by the order in the export file. If the imported server’s
extensions/user limit is exceeded, the remainders are disabled and will not be imported.
The XML export file should not be modified.
Server with version 7.0 will export only user, system extension and Allworx handset parameters and
only a subset of these parameters. Exports from 7.0 can be imported into servers with 7.1 or greater
versions. Exports from 7.1 or greater cannot be imported into servers with 7.0.