4 Mechanical
4.1 Tabletop Placement
To install the Allworx 24x on a tabletop or shelf:
1. Remove the four rubber feet from the packaging.
2. Remove the paper backing from each rubber foot.
3. Turn over the chassis and place one foot at each corner on the bottom of the chassis.
4.2 Rack Mount
To mount the Allworx 24x, 1U high rack mount, inside of a standard 19 inch rack:
1. Verify that there is sufficient clearance around the server’s front and rear panels to allow power, network,
and telephony connections.
2. Place the brackets so that the smaller face of the bracket extends away from the front of the unit to
accommodate installation into the rack (See
Figure 3).
3. Install the mounting brackets on each side of the server chassis using the four 6-32 flat head screws.
4. Proceed to the
Power Connection (Section 5.1) instructions and perform the steps appropriate for your
installation before placing the system into the rack.
5. Install the server into the rack using appropriate hardware.
Figure 3: Rack Mount Bracket Installation