10.3 Door Relay/Paging Amplifier
Unit comes with a single set of C-form relay contacts for connecting to external devices such as remote door
releases and amplifiers. The contacts are rated 30 VDC @ 1A. Connect only: SELV circuits meeting IEC
60950-1 / UL 60950-1 OR NEC Class 2 circuits
Warning: Do not exceed the contact rating.
The connector is shared with the serial port (See page 3, Figure 1, item 5). The pin-out is shown in Table 8
below.
Pin Signal Direction
2 (do not connect) RX Input
3 (do not connect) TX Output
5 (do not connect) GND --
9 Relay COM --
6 Relay NC --
1 Relay NO --
Table 8: Door Relay Pin-Out
To configure the door relay/paging amplifier:
1. Open your browser and enter the URL
http://192.168.2.254:8080 or current LAN IP address for the server.
Refer to
Server Configuration (Section 6).
2. In the Phone System group select Paging.
3. Click Modify in the Page Amplifier area.
4. Select DB9 is connected to a Door Entry System to enable door relay or DB9 is connected to a Paging
Amplifier to enable amplifier.
5. Click Update.
To activate the door relay: Dial extension 403 from any handset connected to the system dial.