Installation Instructions
Allura Fiber Cement Siding Installaon Manual
52
Be sure to install all siding with the proper textured, sealed, or painted surface
facing out.
Do not over drive the fasteners. When a fastener is driven below the surface of the
siding, its holding power is reduced.
Irregularities in framing may be visible in the finished application. To minimize the
effect of uneven walls, shim the wall as necessary.
If you are hand nailing, it may be necessary to predrill to help prevent the corners
from breaking.
NOTE: Because of the random nailing pattern, all panels except Perfection Shingles
must be installed over structural rated sheathing. Fasteners may or may not hit
Perfection Shingles
Perfection Shingles are installed identically to lap siding with the exception of the
following:
To a c h i e ve a S h a k e Se l e c t p a t t e r n , Pe r f e c t i o n Sh i n g l e s m u s t b e i n s t a l l e d w i t h ev e r y
other course rotated 180°.
1. Install the 1st course as described for lap siding.
2. When you install the 2nd course, rotate the panel 180° and fasten.
3. Install the 3rd course with the panel in the same direction as the first, and so on.
Installation Sequence for Perfection Shingles
Shake Select Square Straight Edge and Staggered Edge
Shake Select Square Straight Edge and Staggered Edge panels are produced in three
different panels. Each of these panels has a distinct pattern and is identified by the
number of V-notches cut into the side of the panel.
1. To ensure a random shake look, the panels must be installed in the order shown
on page 55.