4.3 Maintenance
It is highly recommended to check PLOMO-500 routinely. Please check physical of
PLOMO-500 whether the battery is out of expiry date, any damage of main body, wall-bracket,
carry bag, extension bar, buoyant lanyard of package. For clean purpose, do not use any
chemical liquid but fresh water to clean and then wipe dry.
As for functionality-test, more frequent self-testing will consume more energy of battery.
Therefore, the proper periodic self-test of PLOMO-500 should follow Chapter 3.2 every 6
months.
4.4 Replacement
Battery
Since the battery of PLOMO-500 is one-time used primary Lithium battery, it is not rechargeable.
The battery unit should be replaced if PLOMO-500 has been activated, or test mode has been
operated for a cumulative period in excess of 10 times. Also, it should be replaced every 5 year
due to the battery life. The battery replacement must be done by local service Agent.
Red Protection Cover
The Red Protection Cover will be broken after pull-to-break. The replacement of Red Protection
Cover must be done by local service Agent.
4.5 Battery Disposal
The battery must not been incinerate in any time. As for disposal, please check local regulation
first. Generally, end-users should dispose of them through non-profit organization, mandated by
local governments or organized on a voluntary basis by professional. Lithium batteries should
have their terminals insulated prior to disposal.