C: INSTALLING THE OPERATOR
WIRING A 3-BUTTON STATION
NOTE: THREE BUTTON STATIONS MAY BE ORDERED WITH
THE STOP BUTTON AS NORMALLY OPEN OR NORMALLY
CLOSED. THE RS1000 WILL OPERATE ONLY WITH A
NORMALLY OPEN STOP BUTTON. See Figure 12 for instructions
on wiring a three button station.
WIRING A KEYPAD, CARD READER OR
TELEPHONE ENTRY SYSTEM
These devices activate the RS1000 by a relay contact closure within the
device. Typically, two wires or terminals are provided by the device to
operate the gate. Follow the manufacturers instructions on locating
these connections. If one of the connections at the device is labeled as
COMMON, then connect this to Terminal #1 or #0 of the RS1000
control panel. Connect the other contact to one of the following
terminals depending on function desired: Terminal #2 (ALTERNATE),
Terminal #4 (RADIO OPEN), Terminal #5 (FREE EXIT), Terminal #6
(OPEN) or Terminal #7 (CLOSE). If no identification of the
connections is noted at the device, then the two wires may be connected
to terminals #1 and one of the terminals above (again depending on
desired function) in any order.
Keypads, Card Readers and Telephone Entry Systems are typically
located remotely from the RS1000. The wiring used is low voltage
CLASS 2. Be sure to run an independent conduit for this wiring from
the entry device to the RS1000. The wire size should be #16 or #18
stranded for ease of handling.
WIRING VEHICLE DETECTORS
There are three connections that need to be made; 1) the AC power to
the detector, 2) the control connection to the RS1000, and 3) the
connection to the loop. All these connections will be made at the
vehicle detector connector. Follow the wiring instructions provided by
the vehicle detector manufacturer.
VEHICLE DETECTOR POWER
Vehicle detectors may be ordered for 115 VAC or 24 VAC operation.
Allstar recommends that a 115 VAC Vehicle Detector be used. The 115
VAC may be obtained from the electrical service to the RS1000
operator .
RISK OF ENTRAPMENT!
TO REDUCE THE RISK OF INJURY OR DEATH:
LOCATE KEYPAD, CARD READER, KEY SWITCH OR
SIMILAR ENTRY DEVICES IN A LOCATION WHERE A
USER CAN NOT REACH THROUGH THE GATE OR
FENCE TO ACTIVATE THE GATE OPERATOR. THE
RECOMMENDED DISTANCE BETWEEN THE GATE OR
FENCE AND ACCESSORY SWITCH IS 10 FEET.
WARNING!
USE THE 6-TERMINAL STRIP TO POWER
A RADIO RECEIVER ONLY. POWERING
ANY OTHER ACCESSORY DEVICE FROM
THE 6-TERMINAL STRIP MAY RESULT
IN DAMAGE TO THE POWER
TRANSFORMER IN THE OPERATOR.
CAUTION!
110492 Rev. C
Figure 13: Schematic & Wiring Diagram